FullPIERS shows limited performance in Swedish preeclampsia cohort

In an external validation study of 617 Swedish women with preeclampsia, the fullPIERS model had modest discrimination for adverse maternal outcomes at 48 hours and seven days. Performance was better when hematological outcomes were excluded, but the authors concluded that overall clinical utility was poor.

Researchers externally validated the fullPIERS clinical prediction model using data from two prospective Swedish cohort studies. The analysis included 617 women enrolled between May 2019 and March 2025. Predictors were assessed within 24 hours of inclusion, and maternal outcomes were evaluated at 48 hours and seven days. Model performance was assessed by area under the receiver operating characteristic curve (AUC) and by risk classification at prespecified thresholds.

Adverse maternal outcomes occurred in 34 women (5.5%) within 48 hours and 68 (11.0%) within seven days. The AUC was 0.64 at both time points when all outcomes were included. Excluding hematological outcomes increased the AUC to 0.79 within 48 hours and 0.78 within seven days, based on 14 and 19 nonhematological events, respectively. At a predicted-risk threshold below 1%, 297 women were classified as low risk; one had a nonhematological adverse outcome within 48 hours.

The authors concluded that the model had poor overall clinical utility for identifying low- and high-risk women in this cohort. The improved performance for nonhematological outcomes suggests possible use in surveillance decisions, but the small number of such events limits interpretation. The findings do not establish that care should be changed based on the model.

In practice

For Swedish women with preeclampsia, this external validation found that fullPIERS had only modest discrimination for adverse maternal outcomes when hematological outcomes were included (AUC 0.64 at 48 hours and seven days). Discrimination was higher after excluding hematological outcomes, but those analyses included few events. The results do not support relying on the model alone to determine surveillance intensity or changing practice; its performance and clinical utility require further evaluation in relevant settings.

AI-generated clinical interpretation · Not editor-reviewed

AI summary · Not yet editor-reviewed

Is this summary clinically accurate?

Help fellow clinicians: your rating sends inaccurate summaries straight to our editors.

Sign in to rate this summary →

Source

Acta Obstetricia et Gynecologica Scandinavica: External validation of the fullPIERS model for predicting adverse maternal outcomes among Swedish women with preeclampsia ↗