← All updates
Clinical trial

Gastroenterology ·

Anchored covered stents reduced dysfunction in distal malignant biliary obstruction

In a multicenter randomized trial at nine South Korean referral centers, 99 patients with unresectable distal malignant biliary obstruction were analyzed after assignment to an externally anchored fully covered metal stent or an uncovered metal stent. Stent dysfunction was less frequent with the anchored covered stent, while adverse events and overall survival did not differ.

Self-expandable metal stents are commonly used to relieve malignant biliary obstruction. This multicenter randomized trial enrolled patients with unresectable distal obstruction at nine tertiary referral centers in South Korea between October 2021 and February 2024. Participants were assigned to an externally anchored fully covered metal stent with a plastic stent (FCSEMS-EPS) or an uncovered metal stent (USEMS), with follow-up for 12 months. The primary outcome was biliary stent dysfunction. Of 113 enrolled patients, 99 were included in the final analysis: 48 in the FCSEMS-EPS group and 51 in the USEMS group.

Stent dysfunction occurred in 27.1% of patients receiving FCSEMS-EPS and 49.0% receiving USEMS (P=0.04). The six-month cumulative incidence was 21.1% versus 29.8%, respectively (Gray’s test P=0.03). In a multivariable competing-risk analysis, FCSEMS-EPS was associated with a lower risk of dysfunction (subdistribution hazard ratio 0.44, 95% CI 0.21–0.90; P=0.03). Procedure-related adverse events and overall survival did not differ between groups.

The findings suggest a potential patency advantage for the anchored covered-stent strategy in this population, without a detected increase in procedure-related adverse events. Interpretation is limited by the 99-patient final analysis and the study’s setting in nine South Korean tertiary centers; the abstract does not provide details on reasons for exclusion or individual adverse-event rates.

In practice

For patients with unresectable distal malignant biliary obstruction, this randomized trial suggests that an externally anchored fully covered metal stent may reduce stent dysfunction compared with an uncovered metal stent. The comparison included 99 patients in the final analysis, and procedure-related adverse events and overall survival did not differ. These findings may inform consideration of stent choice, but the evidence comes from a relatively small trial at nine South Korean tertiary centers; it does not establish a universal preferred approach.

AI-generated clinical interpretation · Not editor-reviewed

AI summary · Not yet editor-reviewed

Is this summary clinically accurate?

Help fellow clinicians: your rating sends inaccurate summaries straight to our editors.

Sign in to rate this summary →

Source

Endoscopy: Externally anchored fully covered metal stents with plastic stent versus uncovered metal stents for unresectable distal malignant biliary obstruction: a multicenter randomized trial ↗

This is an automated AI-condensed summary that has not yet been reviewed by an editor. Always consult the full item at the original source.