Prone positioning altered simulated staff aerosol exposure during respiratory support
A two-manikin bench study tested aerosol exposure across 32 combinations of patient position, respiratory interface, breathing pattern and staff location. Prone positioning was associated with lower simulated inhaled aerosol concentrations in most comparisons, but exposure increased in one CPAP configuration; the findings require confirmation in real clinical settings.
- Prone positioning lowered aerosol levels in 13 of 16 comparisons.
- HFNC head-side exposure was lower when the patient was prone.
- Head-side exposure increased with prone positioning in one CPAP setup.
- A manikin model limits clinical interpretation.
Researchers used a breathing source manikin and a masked receiver manikin positioned 50 cm apart in a negative-pressure room. They measured aerosol inside the receiver’s mask across 32 configurations involving prone or supine positioning, four respiratory interfaces, two breathing patterns and staff placement at the head or trunk. Aerosol plume direction was also visualised.
In 13 of 16 paired comparisons, prone positioning was associated with lower in-mask aerosol concentration. Across those conditions, the mean fell from 235.7 to 115.3 parts per million (a 51.1% reduction). The largest reported reductions were 74.5% at the trunk without a device during hyperpnoea and 60.1% at the head with high-flow nasal cannula (HFNC). In contrast, head-side exposure with a sealed CPAP mask during eupnoea was higher when prone. Three key comparisons were repeated on three separate days, reproducing the direction of the findings.
The results suggest that patient position and staff approach angle may influence simulated aerosol exposure, with effects varying by interface. However, this was a single-geometry model using a physical tracer rather than a pathogen; most configurations had only one qualifying run, and positioning changes also involved differences in bed angle and head rotation. The findings are hypothesis-generating and do not establish reduced infection risk or support changing clinical practice.
In practice
In this manikin model, prone positioning was associated with lower simulated aerosol inhalation in most tested configurations, including with HFNC, but the effect depended on the interface and staff location; one CPAP configuration showed higher exposure when prone. These findings may inform questions about staff positioning during care, but they do not demonstrate reduced transmission or infection risk. The single-geometry setup, physical tracer, and limited repeat testing mean the results are hypothesis-generating and do not justify changing patient positioning or infection-control practice.