← All updates
Meta-analysis

Surgery ·

Robotic and open pancreatoduodenectomy show similar perioperative safety

A meta-analysis of four randomized trials involving 765 adults found no significant differences between robotic and open pancreatoduodenectomy in severe morbidity, clinically relevant pancreatic fistula, or 90-day mortality. Robotic surgery was associated with lower estimated blood loss, but direct procedural costs were higher and evidence certainty varied.

This systematic review and meta-analysis compared robotic pancreatoduodenectomy (RPD) with open pancreatoduodenectomy (OPD) in adults. The authors searched databases and trial registries, then included four randomized controlled trials with 765 participants. Outcomes included severe postoperative morbidity, grade B/C postoperative pancreatic fistula (POPF), 90-day mortality, blood loss, length of stay, recovery, and costs. Trials were also assessed for risk of bias, evidence certainty, and procedural-development stage using the IDEAL framework.

RPD did not significantly differ from OPD in severe morbidity (RR 0.92, 95% CI 0.75–1.13), grade B/C POPF (RR 0.88, 95% CI 0.58–1.32), or 90-day mortality (RR 0.81, 95% CI 0.24–2.79). Estimated blood loss was 70.6 mL lower with RPD, although heterogeneity was high (I²=78%). Direct procedural costs were higher with RPD in contributing trials; total admission costs varied by setting. Certainty was moderate for severe morbidity and low for the other reported primary outcomes.

The findings support comparable perioperative safety in experienced programs, but do not establish broad superiority of RPD. The authors report more favorable POPF and length-of-stay results in sensitivity analyses limited to IDEAL Stage 3 trials. These subgroup findings and the low-certainty evidence for several outcomes warrant caution. The supplied abstract states that searches ran through July 2026; this date should be verified against the publication record.

In practice

For adults undergoing pancreatoduodenectomy, this synthesis of four randomized trials suggests that robotic surgery has perioperative safety outcomes broadly similar to open surgery in the studied settings. It does not establish a clear clinical advantage: the estimated reduction in blood loss was modest and heterogeneous, while direct procedural costs were consistently higher. Evidence certainty was low for fistula, mortality, and blood loss, and favorable findings in Stage 3 trial sensitivity analyses are not definitive. The results do not by themselves justify changing operative approach.

AI-generated clinical interpretation · Not editor-reviewed

AI summary · Not yet editor-reviewed

Is this summary clinically accurate?

Help fellow clinicians: your rating sends inaccurate summaries straight to our editors.

Sign in to rate this summary →

Source

Annals of Surgery: Robotic Versus Open Pancreatoduodenectomy ↗

This is an automated AI-condensed summary that has not yet been reviewed by an editor. Always consult the full item at the original source.