← All updates
Observational study

Pulmonology · Internal Medicine ·

Oxygen tolerance unit showed limited value in ICU-ROX secondary analysis

A secondary analysis of 965 invasively ventilated adults in the ICU-ROX trial assessed whether the oxygen tolerance unit (OTU) could measure cumulative pulmonary oxygen exposure and predict 90-day mortality. OTU was associated with mortality, but performed no better than mean PEEP, and its conventional FiO₂ threshold was not supported by the data.

Researchers calculated cumulative OTU from six-hourly FiO₂ readings on days 0–10 for 965 ICU-ROX participants. OTU, a measure adapted from diving medicine, estimates cumulative pulmonary oxygen exposure and assigns no dose at or below an inspired oxygen pressure corresponding to FiO₂ 0.50 at sea level. The analysis examined the frequency of exposure, the fit of the formula’s threshold and exponent, and associations with mortality.

Median cumulative OTU was 0 (IQR 0–95), and 67% of patients accrued no dose from the sampled readings. Exposure was concentrated in patients with severe hypoxaemia. OTU was associated with 90-day mortality (adjusted OR 1.13 per 100-unit increase; 95% CI 1.06–1.21), but fitted no better than mean PEEP. The best-fitting FiO₂ cut-off against mortality was 0.21, outside the supported range for the published threshold.

The findings do not establish that oxygen exposure caused deaths: illness severity may account for the association, and model fit cannot distinguish severity from toxicity. The comparison between randomized groups among patients who accrued any dose also conditions on a post-randomisation variable. This secondary analysis suggests the OTU formula, particularly its 0.50 threshold, may be poorly suited to unselected ventilated patients; it does not establish a clinical use for the measure.

AI summary · Not yet editor-reviewed

Is this summary clinically accurate?

Help fellow clinicians: your rating sends inaccurate summaries straight to our editors.

Sign in to rate this summary →

Source

Critical Care: Use of the oxygen tolerance unit to measure potential pulmonary oxygen toxicity in critically ill patients? A secondary analysis of the ICU-ROX randomised trial ↗

This is an automated AI-condensed summary that has not yet been reviewed by an editor. Always consult the full item at the original source.